Groen CNEB/24 HyPlus Steamers (Countertop & Floor)
Groen CNEB/24 HyPlus Steamers (Countertop & Floor) is backordered and will ship as soon as it is back in stock.
Documents
Related Searches
Reach out via chat, email, or phone—we're here to help make sure it's the right fit for your kitchen. Contact us for more information.
Description
HyPlus™ CNEB-24 Electric Pressure Steam Boiler
24 in. cabinet base • 2.2 BHP • CSD-1 compliant • Made in the USABuilt for high-volume commercial kitchens that need on-demand steam without a dedicated boiler room, the Groen HyPlus™ CNEB-24 delivers a robust 2.2 boiler horsepower (24 kW) in a compact 24 inch footprint. Its stainless-steel cabinet, intuitive controls and automatic safety systems make it the ideal steam source for connected kettles, steamers or other equipment rated for up to 15 PSI.
Why Choose the HyPlus™ CNEB-24
- Instant steam, small footprint —24 kW heating elements generate 2.2 BHP while occupying just 24⅜ in. of line space.
- Stainless-steel durability —Cabinet, front panel and bullet feet are all corrosion-resistant 304 stainless with a #3 uniform polish.
- Operator-friendly controls —Power and start switches, reset indicator, external pressure gauge, water-level sight glass and low-water sensor keep everything visible and safe.
- Automatic safety shutdown —Unit powers down on low water or over-pressure and drains itself once the boiler cools to 170 °F.
- Steam take-off ready —½ in. NPT power take-off valve lets you pipe steam directly to Groen kettles, steamers and other appliances.
- Certified & compliant —ASME pressure vessel, National Board registered, CSD-1 compliant and cULus listed.
Technical Specifications
Steam capacity | 2.2 BHP / 24 kW |
---|---|
Operating pressure | 0 – 15 PSI |
Voltage / phase | 208 V / 60 Hz / 3 Ø (67 A) 240 V / 60 Hz / 3 Ø (58 A) 480 V / 60 Hz / 3 Ø (29 A) |
Cabinet width | 24 ⅜ in. / 619 mm |
Cabinet depth | 34 ½ in. / 876 mm |
Overall height | 28 ¾ in. / 730 mm |
Drain connection | 1-¼ in. NPT (boiler & condensate spray) |
Treated water inlet | ½ in. NPT |
Untreated water inlet | ½ in. NPT (condensate spray) |
Steam power take-off | ½ in. NPT |
Construction | All stainless steel cabinet with louvered, lift-off front panel |
Feet | Adjustable bullet feet |
Certifications | ASME, National Board, cULus, CSD-1 |
Origin | Made in USA |
Required Water Quality
Pressure | 30 – 60 PSI |
---|---|
pH | 7 – 9 |
Hardness | < 60 ppm |
TDS | 30 – 60 ppm |
Chlorine / Chloramine | < 0.1 ppm |
Total chloride | < 30 ppm |
Silica | < 12 ppm |
Undissolved solids | < 5 micron |
Maintaining the above water quality is essential to preserve warranty coverage and maximize generator life.
Popular Factory-Options
- Prison package
- Delimer / Descaler or Degreaser starter kits
- Field drain tempering kit
- 6 ft or 12 ft inter-connecting piping harness
- Flanged feet set
- PureSteam replacement cartridge or full pre-filter system
- Single water connection manifold
Warranty & Support
Every HyPlus boiler ships with Groen’s standard 1-year parts & labor warranty (2-year with Groen authorized start-up). Extended coverage is available at the time of purchase. Technical assistance is only a phone call away at 888-994-7636.