Key specifications

Amps
3 x 6.4 Amps
Phase
3-Phase
Dimensions
59.06"W × 138.39"D × 87.8"H
Type
Blast Chiller
Style
Roll-Thru
Installation Type
Floor Model
Spec sheet

Piper Products/Servolift Eastern RDMC83T 60-Pan Roll-Thru Blast Chiller

$113,402.64
/each
Estimated to ship in 41–44 business days

Ships by freight. At about 3,174 lb it’s too heavy for a liftgate, so delivery needs a loading dock or a forklift rated for at least 6,000 lb with 6-ft forks.

Made to order. Lead times are estimates and can change with the factory’s production schedule. You can cancel free within 24 hours of ordering if production hasn’t started. Once it starts, canceling may not be possible or may carry the manufacturer’s cancellation fee.

Function
Chilling capacity
Door configuration
Floor
Included: Piper Products/Servolift Eastern warranty 12-month limited warranty on parts and labor

Get priority processing and free 1-year protection with PREMIUM Learn about Premium

As low as $10,490/mo with Credit Key Learn more

Questions before you buy?

Talk to a specialist Mon–Fri 8am–6pm CT. We usually reply within 1 hour.

Questions before you buy?

Talk to an equipment specialist about voltage, installation or the right size for your kitchen.
Usually within 1 hour during business hours (Mon–Fri 8am–6pm CT).

Specifications

Type Blast Chiller
Style Roll-Thru
Installation Type Floor Model
Material Stainless Steel
Finish Scotch-Brite
Pan Capacity 60 Sheet Pans or 120 Steam Table Pans
Pan Size 18 x 26 in Sheet Pans; 12 x 20 in Steam Table Pans
Chilling Capacity 992 lb per 90-Minute Cycle
Freezing Capacity 661 lb per 240-Minute Cycle
Temperature Range 194°F to 37°F Chilling; 194°F to 0°F Freezing
Controls T Electronic Control Board with Display
Refrigeration Type Remote
Refrigerant Type R404A
Voltage 208/240 Volts
Amps 3 x 6.4 Amps
Watts 3 x 2.02 kW
Hertz 60 Hz
Phase 3-Phase
Wiring Field Wired

Description

The RDMC83T is a roll-thru shock freezer and blast chiller with stainless steel interior and exterior construction. It accommodates 60 18 x 26 in sheet pans or 120 12 x 20 in steam table pans.

  • Chilling: 194°F to 37°F cycle with a 992 lb capacity.
  • Freezing: 194°F to 0°F cycle with a 661 lb capacity.
  • Controls: T electronic control board with display and a heated core probe.
  • Construction: Leak-proof floor, stainless steel interior and exterior, and doors with locks and anti-condensation heating elements.
  • Refrigeration: Remote refrigeration is required and is not included. Uses R404A refrigerant.

Overall Dimensions:

59.06"W x 138.39"D x 87.8"H

Product Weight:

3174.0 lb

Roll-Thru Configuration

Built as a roll-thru shock freezer/blast chiller for the listed pan capacities.

Pan Capacity

Accommodates 60 18 x 26 in sheet pans or 120 12 x 20 in steam table pans.

Chilling Cycle

Chills from 194°F to 37°F with a 992 lb capacity.

Freezing Cycle

Freezes from 194°F to 0°F with a 661 lb capacity.

Electronic Control

T electronic control board includes a display.

Heated Core Probe

Includes a heated core probe.

Door Features

Doors have locks and anti-condensation heating elements.

Leak-Proof Floor

The interior bottom and floor are leak-proof.

Stainless Steel Construction

Interior and exterior are stainless steel.

Remote Refrigeration

Remote refrigeration is required and is not included.

R404A Refrigerant

Uses R404A refrigerant.

Field-Wired Electrical Service

Requires 208/240 Volts, 60 Hz, 3-Phase service with three 6.4 Amp circuits and three 2.02 kW inputs; field wired.

Frequently Asked Questions

It accommodates 60 18 x 26 in sheet pans or 120 12 x 20 in steam table pans.
The chilling cycle has a 992 lb capacity from 194°F to 37°F. The freezing cycle has a 661 lb capacity from 194°F to 0°F.
Remote refrigeration is required, and the refrigeration system is not included.
The unit requires 208/240 Volts, 60 Hz, 3-Phase service, three 6.4 Amp circuits, three 2.02 kW inputs, and field wiring.
Yes. It includes a heated core probe.
The listed dimensions are 59.06 in wide, 138.39 in deep, and 87.8 in high, with a listed weight of 3,174 lb.

This ships by freight truck on a pallet, not by a parcel carrier. The carrier calls ahead to set a delivery window, and an adult 18 or older must be there to receive, inspect and sign for it.

It’s too heavy for a liftgate, so you need a loading dock, or a forklift rated for at least 6,000 lb with 6-ft forks and an operator on site. The driver won’t unload it.

Getting ready for a dock or forklift delivery

  • Count every piece against the delivery receipt.
  • Check every side for crushed corners, torn wrap, punctures, water stains or a tipped unit.
  • Photograph the freight on the truck before it’s moved.
  • If you see any damage, even cosmetic, write “DAMAGED” and what you see on the receipt before you sign.

Your shipping email has the exact instructions for your order. Questions at the door? Call us at (888) 307-5030.

How to inspect and sign for freight

Keep all the packaging, photograph the damage and the packaging, and tell us within 5 business days of delivery. Reply to your shipping email with the photos or call (888) 307-5030.

If the driver won’t wait while you inspect, write “Received – pending inspection. Driver would not wait.” with the date and time on the receipt, then inspect right away and report any damage within 24 hours.

Reporting damage after delivery

Book your installer only after the carrier gives you a firm delivery appointment. Freight dates can move, and installer trips lost to a late truck aren’t reimbursable.

Need help deciding?

Our specialist can help you confirm dimensions, building requirements, and other important details before you buy. We usually reply within 1 hour during business hours (Mon–Fri 8am–6pm CT).

or call (888) 307-5030