Perlick Corporation

Perlick Bevchek Telemetry Kit for One Power Pak with One Pump

SKU: 1053622
$1,983.30
/each
Free Shipping
Expected delivery date of ,
if ordered within hours and minutes
Not Shipping to ?
Want to speak to an expert?

Perlick Bevchek Telemetry Kit for One Power Pak with One Pump

Complete kit with Comnode, 16-Port Hub, and Temperature/Flow Sensors

A complete telemetry package that connects one Power Pak and one pump to Bevchek monitoring and reporting.

  • Built for one Power Pak with one pump.
  • Includes a Comnode, 16-port Hub, cooler air sensor, cooler fluid sensor, glycol bath sensor, and glycol flowmeter.
  • Helps monitor cooler air, cooler fluid, glycol bath temperature, and glycol flow conditions.
  • Included Comnode supports cellular and Ethernet communication for telemetry data collection.
  • Standard sensor cable lengths and an extension option help accommodate different draft system layouts.

Complete One-Pump Kit

Configured for one Power Pak with one pump, making it a complete telemetry solution for a single draft system setup.

Included System Components

Ships with one Comnode, one 16-port Hub, one cooler air temperature sensor, one cooler fluid temperature sensor, one glycol bath temperature sensor, and one glycol flowmeter.

Multi-Point Monitoring

Tracks cooler air temperature, cooler fluid temperature, glycol bath temperature, and glycol flow so draft conditions can be monitored from multiple points.

16-Port Telemetry Hub

The included hub provides 16 sensor ports and is the central collection point for connected sensors.

Cellular And Ethernet Comnode

The comnode provides cellular and Ethernet communication for telemetry connectivity and data transmission.

Glycol Flowmeter Compatibility

The included flowmeter is designed for glycol lines with 3/8 inch and 1/2 inch ID using John Guest quick connect connections.

Type Telemetry Kit
Style For One Power Pak, One Pump
Selling Unit Each
Units Per Case 1
Shipping Weight 9 lb.

Frequently Asked Questions

The kit includes one Comnode, one 16-port Hub, one cooler air temperature sensor, one cooler fluid temperature sensor, one glycol bath temperature sensor, and one glycol flowmeter.
This model is for one Power Pak with one pump. A two-pump version is also referenced as model 1053623.
The included hub has 16 sensor ports and also includes one onboard ambient temperature input.
Yes. The guide notes that the Comnode contains a cellular connection and must be placed outside of the cooler.
Yes. The guide says the system comes with a 25 foot cable standard and can be increased up to 300 feet using standard network hardware.