Description
Krowne MasterTap™ Draft Beer Power Pack – 3/4 HP, 6,950 BTU
Model KPP75-1 | Air-Cooled Glycol ChillerPerfect for busy bars, taprooms and stadium concessions, the Krowne MasterTap™ 3/4 HP Power Pack keeps beer ice-cold from walk-in keg cooler to faucet. A compact stainless-steel cabinet, high-capacity pump and factory-programmed digital thermostat work together to deliver trouble-free performance shift after shift.
Key Features
- 3/4 HP hermetic compressor delivers 6,950 BTU of cooling @ 15 °F evaporator.
- 80 GPH / 100 PSI centrifugal pump maintains steady glycol circulation through long trunk lines.
- Air-cooled, all-stainless cabinet resists corrosion and wipes clean quickly.
- Digital thermostat & display – factory set to 30 °F cut-out with a 2 °F differential.
- 1.8 gal insulated reservoir ships ready for a 33 % propylene glycol / 67 % water mix.
- Hard-wired 120 V / 60 Hz, single-phase connection (no cord or plug included).
- Space-saving footprint: 27 in W × 20 in D × 26 in H.
- ETL-us & ETL-Sanitation listed for peace of mind in commercial environments.
At-a-Glance Specs
Cabinet Construction | 304 stainless steel, air-cooled condenser |
---|---|
Cooling Capacity | 6,950 BTU/hr @ 15 °F evaporator |
Compressor | 3/4 HP, R-134a refrigerant |
Circulating Pump | 80 GPH / 100 PSI |
Reservoir Volume | 1.8 gal (glycol mix 33 % PG / 67 % H₂O) |
Temperature Set Point | 30 °F (adjustable 28 – 34 °F) |
Electrical | 120 V / 60 Hz / 1-ph, hard-wired, 25 A MCA |
Dimensions (W × D × H) | 27 in × 20 in × 26 in |
Shipping Weight | ≈ 159 lb |
Certifications | ETL-us, ETL-Sanitation |
Installation & Operation
- Mount on a level surface with at least 6 in of clearance on all sides for ventilation.
- Ambient operating range: 50 °F – 90 °F (performance diminishes above 100 °F ambient).
- Connect ½ in O.D. coolant supply/return lines and plumb ½ in overflow to a drain.
- Fill reservoir with pre-mixed food-grade glycol before energizing the pump.
- Allow bath to reach 32 °F prior to introducing product into the system.
- All electrical and plumbing connections must be completed by qualified professionals in accordance with local codes.
Recommended Accessories
- KPP-S1 Stainless Steel Stand – elevates unit for easy service and improved airflow.
- KPP-W1-75 Wall Bracket – suspends chiller to free up valuable floor space.
- GL-1 Glycol Premix – 33 % propylene glycol / 67 % distilled water (5 gal).
*Maximum trunk line length depends on line diameter, elevation and number of towers. Please consult Krowne engineering for application-specific sizing.