Follett F1012CU Air-cooled, three phase remote condenser for use with D1012R evaporator unit. Pre-charged, R449a
$6,768.43
/each
Ships in 11–14 business days
- Unit type
- Air-cooled remote condenser
- Compatible evaporator
- D1012R
- Electrical
- 208–230 V / 60 Hz / 3-phase
- Refrigerant
- R449a
- Refrigerant charge
- 8 lb, factory pre-charged
- Operating power
- 1.30 kW
Specifications
Unit type
Air-cooled remote condenser
Compatible evaporator
D1012R
Electrical
208–230 V / 60 Hz / 3-phase
Refrigerant
R449a
Refrigerant charge
8 lb, factory pre-charged
Operating power
1.30 kW
Minimum circuit ampacity
10 A
Maximum circuit HVACR breaker size
15 A
Maximum refrigerant line run
75 ft (22.9 m)
Maximum line rise above evaporator
35 ft (10.7 m)
Maximum evaporator mounting above condenser
15 ft (4.6 m)
Maximum refrigeration line drop without oil trap
15 ft (4.6 m)
Ambient air operating range
-20°F to 120°F (-29°C to 49°C)
Description
The Follett F1012CU is an air-cooled, three-phase remote condenser for use with the D1012R evaporator unit. It is pre-charged with R449a and specified for 208–230 V/60 Hz/3-phase service.
- 40 in width, 34 in depth and 25.25 in height
- Factory pre-charged with 8 lb of R449a refrigerant
Overall Dimensions:
40.0"W x 34.0"D x 25.25"HProduct Weight:
280.0 lbAir-cooled design
Uses air cooling for the remote condenser configuration.
D1012R compatibility
Designed for use with the D1012R evaporator unit.
Factory-pre-charged refrigerant
Includes an 8 lb factory charge of R449a refrigerant.
Three-phase electrical service
Specified for 208–230 V/60 Hz/3-phase service.
Extended refrigerant line allowance
Supports a maximum refrigerant line run of 75 ft (22.9 m).
Ambient operating range
Outdoor condensing unit operating limits are -20°F to 120°F (-29°C to 49°C) air temperature.
Documentation
Certifications & Compliance
Frequently Asked Questions
The F1012CU is for use with the D1012R evaporator unit.
It uses R449a and is factory pre-charged with 8 lb of refrigerant.
The unit is specified for 208–230 V, 60 Hz, three-phase electrical service.
The maximum refrigerant line run is 75 ft (22.9 m).
The unit is 40 in wide, 34 in deep and 25.25 in high.
The warranty is 3 years for parts and labor, with 5 years for compressor parts.