Follett C1812CU Air-cooled, single phase remote condenser for use with D1812R evaporator unit. Pre-charged, R449a
$11,331.58
/each
Ships in 11–14 business days
- Product type
- Air-cooled, single-phase remote condenser
- Compatible evaporator unit
- D1812R
- Electrical
- 208-230/60/1
- Operating power
- 2.16 kW
- Minimum circuit ampacity
- 20 A
- Maximum circuit HVACR breaker size
- 30 A
Specifications
Product type
Air-cooled, single-phase remote condenser
Compatible evaporator unit
D1812R
Electrical
208-230/60/1
Operating power
2.16 kW
Minimum circuit ampacity
20 A
Maximum circuit HVACR breaker size
30 A
Refrigerant
R449a
Refrigerant charge
11 lb, pre-charged at factory
Maximum refrigerant line run length
75 ft (22.9 m)
Maximum line rise above evaporator
35 ft (10.7 m)
Evaporator mounting above condenser
15 ft (4.6 m)
Maximum refrigeration line drop without oil trap
15 ft (4.6 m)
Outdoor condensing unit operating limits
-20°F to 120°F (-29°C to 49°C) air temperature
Description
The Follett C1812CU is an air-cooled, single-phase remote condenser for use with the D1812R evaporator unit.
- Factory pre-charged with 11 lb of R449a refrigerant.
- Electrical specification: 208-230/60/1.
- Specified for outdoor condensing unit air temperatures from -20°F to 120°F (-29°C to 49°C).
Overall Dimensions:
40.0"W x 34.0"D x 36.5"HProduct Weight:
285.0 lbAir-cooled remote condenser
Designed as an air-cooled remote condenser for a remote ice machine installation.
D1812R compatibility
Specified for use with the D1812R evaporator unit.
Factory pre-charged
Factory pre-charged with 11 lb of R449a refrigerant.
Single-phase electrical service
Uses 208-230/60/1 electrical service.
Refrigerant line range
The specified maximum refrigerant line run length is 75 ft (22.9 m), with a maximum line rise above the evaporator of 35 ft (10.7 m).
Operating limits
Outdoor condensing unit operating limits are -20°F to 120°F (-29°C to 49°C) air temperature.
Documentation
Certifications & Compliance
Frequently Asked Questions
The C1812CU is specified for use with the D1812R evaporator unit.
It uses R449a and is factory pre-charged with 11 lb.
Its electrical specification is 208-230/60/1.
The specified maximum refrigerant line run length is 75 ft (22.9 m).
The listed dimensions are 40 in wide, 34 in deep, and 36.5 in high.
The outdoor condensing unit operating limits are -20°F to 120°F (-29°C to 49°C).