Follett C1012CU Air-cooled, single phase remote condenser for use with D1012R evaporator unit. Pre-charged, R449a

$6,652.64
/each
Ships in 11–14 business days
Product type
Air-cooled remote condenser
Compatible evaporator
D1012R
Electrical
208–230 V/60 Hz/1 ph
Refrigerant
R449a
Factory refrigerant charge
8 lb, pre-charged at factory
Operating power
1.30 kW

Questions before you buy?

Talk to an equipment specialist — usually within 1 hour, 9am–6pm EST.

Specifications

Product type Air-cooled remote condenser
Compatible evaporator D1012R
Electrical 208–230 V/60 Hz/1 ph
Refrigerant R449a
Factory refrigerant charge 8 lb, pre-charged at factory
Operating power 1.30 kW
Minimum circuit ampacity 11 A
Maximum HVACR breaker size 15 A
Outdoor condensing unit operating limits -20 to 120 °F (-29 to 49 °C) air temperature
Maximum refrigerant line run 75 ft (22.9 m)
Maximum line rise above evaporator 35 ft (10.7 m)
Maximum evaporator mounting above condenser 15 ft (4.6 m)
Maximum refrigeration line drop without oil trap 15 ft (4.6 m)

Description

C1012CU is an air-cooled, single-phase remote condenser for use with the Follett D1012R evaporator unit. It is factory pre-charged with R449a and uses 208–230 V, 60 Hz, single-phase electrical service.

  • Operating power: 1.30 kW
  • Maximum refrigerant line run: 75 ft (22.9 m)
  • Factory refrigerant charge: 8 lb of R449a

Overall Dimensions:

40.0"W x 34.0"D x 25.25"H

Product Weight:

280.0 lb

Air-cooled remote condenser

Provides air-cooled remote condensing for the D1012R evaporator unit.

Single-phase electrical service

Specified for 208–230 V, 60 Hz, single-phase operation.

Factory-precharged refrigerant system

Pre-charged at the factory with 8 lb of R449a.

Remote installation range

Supports a maximum refrigerant line run of 75 ft (22.9 m).

Outdoor operating limits

Specified operating air temperature range is -20 to 120 °F (-29 to 49 °C).

Installation elevation limits

The maximum line rise above the evaporator is 35 ft (10.7 m), and the evaporator may be mounted up to 15 ft (4.6 m) above the condenser.

Documentation

Certifications & Compliance

Certified badge of ETL Listed
ETL Listed
Certified badge of NSF Certified
NSF Certified
Certified badge of UL Certified
UL Certified

Frequently Asked Questions

The C1012CU is specified for use with the D1012R evaporator unit.
It requires 208–230 V, 60 Hz, single-phase electrical service.
It uses R449a and is pre-charged at the factory with 8 lb.
The maximum refrigerant line run is 75 ft (22.9 m).
The listed dimensions are 40 in wide, 34 in deep, and 25.25 in high.
The product documentation specifies 3 years on parts and labor and 5 years on compressor parts.

Need help deciding?

Our specialist can help you confirm dimensions, building requirements, and other important details before you buy. We usually reply within 1 hour.

or call (888) 307-5030

Request a price match

Found this item for less elsewhere? Send us the listing and we'll review it — usually within 1 hour, 9am–6pm EST.

https://www.youtube.com/watch?v=chbxp_2xrik

Follett C1012CU Air-cooled, single phase remote condenser for use with D1012R evaporator unit. Pre-charged, R449a

C1012CU · Our price $6,652.64/each